В работе предложена комплексная технология очистки фильтрационных вод полигонов твердых бытовых отходов, которая позволяет очистить стоки до требований ПДК для вод рыбохозяйственного назначения.

Ключевые слова: охрана окружающей среды, фильтрационные воды, очистка.

PURIFICATION OF LEAKAGE WATERS FROM SOLID HOUSEHOLD WASTE POLYGON

Povarov A.A. ¹, Selivanova N.V. ², Trifonova T.A. ², Pavlova V.F.¹, Selivanov O.G.², Ilyma M.E. ², Shirkin L.A. ², Torshin V.B. ³

¹ JSC "BMT", city of Vladimir
² Vladimir state university named after A.G. and N.G. Stoletovs, city of Vladimir
³ Karpov Institute of Physical Chemistry, Moscow

In work the complex technology of purišcation the leakage waters from solid household waste polygon which allows to clear drains to maximum concentration limit requirements for waters of šshery appointment is o›ered.

Key words: environmental protection, leakage waters, purišcation.

‹ˆ 628.3
 
МЕТОДИКА ОПРЕДЕЛЕНИЯ РАСЧЕТНЫХ ПОКАЗАТЕЛЕЙ РАСХОДА И СОСТАВА СТОЧНЫХ ВОД

Соловьева Е.А., канд. техн. наук, доцент,
Петербургский государственный университет путей сообщения Императора Александра I, г. Санкт-Петербург;
Мишуков Б.Г., д-р техн. наук, профессор,
Петербургский государственный архитектурно-строительный университет, г. Санкт-Петербург

В статье рассмотрены изменения поступления по растворенной части загрязнений (азот аммонийный) и ХПК по концентрации и массе. Предложен вариант раздельного рассмотрения поступления бытового стока и смеси бытового и дождевого стоков. Показаны зависимости поступления расхода сточных вод, концентрации и массы загрязнений в зависимости от обеспеченности притока сточных вод на очистные сооружения. Практическая значимость: отображение суточного расхода смеси дождевых и бытовых сточных вод в виде математической зависимости позволяет составить расчетные показатели работы очистных сооружений г. Санкт-Петербурга. На основе ожидаемой погоды по данным метеослужбы можно составить прогноз поступления массы сточных вод и разработать план мероприятий по очистке стоков.

Ключевые слова: сточные воды, дождевые сточные воды, общесплавная канализация, состав стоков, очистные сооружения канализации, ХПК азот аммонийный.

A METHOD FOR ESTIMATION OF CALCULATED RATES OF WASTEWATER FLOW AND COMPOSITION

Solovyeva E.A., Dr. habil. of technical sciences, professor,
St. Petersburg state university of architecture and civil engineering, St. Petersburg;
Mishukov B.G., Ph.D. of technical sciences, associate professor,
Emperor Alexander I St. Petersburg state transport university, St. Petersburg

The study looks at changes in dissolved part of contaminants (Ammonia Nitrogen) and COD by concentration and mass. An option for separate consideration of household žow and mixture of household and rain žow is proposed. Dependencies between wastewater žow, concentration and mass of contaminants are shown in relation to the žow of wastewater to wastewater treatment plants. Practical importance: Showing daily volumes of mixture of rain and household wastewater as a mathematical formula allows to compile calculated rates for the operation of St Petersburg municipal wastewater treatment plants. On the basis of weather expected from weather station forecasts, a forecast of the mass of wastewater can be compiled, and measures to treat wastewater can be planned.

Key words: wastewater, storm water, combined sewer, contaminants, wastewater treatment plants, COD, Ammonia Nitrogen.

УДК 628.16.067.3(571.66-25)

ИССЛЕДОВАНИЕ ЭФФЕКТИВНОСТИ ПРИМЕНЕНИЯ МЕМБРАННЫХ ФИЛЬТРОВ ДЛЯ ОЧИСТКИ ПРИРОДНЫХ ВОД ОТ ВОДОЗАБОРНЫХ СООРУЖЕНИЙ ГУП «ПЕТРОПАВЛОВСКИЙ ВОДОКАНАЛ»

Потапов В.В.,
Научно-исследовательский геотехнологический центр ДВО РАН, г. Петропавловск-Камчатский;
Бровкин А.Е., ГУП «Петропавловский водоканал», г. Петропавловск-Камчатский

Исследовано молекулярно-массовое строение растворенного органического вещества в природной воде водозаборных сооружений ГУП «Петропавловский водоканал» методом гель-проникающей хроматографии. Приведены результаты экспериментов применения керамических микрофильтрационных фильтров с диаметром пор 0,2 и 0,07 мкм для очистки природных вод в ГУП «Петропавловский водоканал», а также по снижению цветности и мутности природной воды с помощью ультрафильтрационных фильтров. Экспериментально установлена высокая эффективность применения мембранных устройств для очистки природной воды с водозаборных сооружений ГУП «Петропавловский водоканал». Показатели селективности для микрофильтрационных фильтров составили: по цветности – до 84 %, по мутности – до 100 %; для ультрафильтрационных фильтров: по цветности – до 80 %, по мутности – до 100 %. Внедрение рассматриваемой технологической схемы водоподготовки нового поколения на территории Камчатского края позволит значительно повысить эффективность очистки природной воды.

Ключевые слова: молекулярно-массовое распределение растворенного органического вещества, мембранные фильтры, мутность воды, цветность воды, показатели селективности мембранных фильтров.

STUDY ON MEMBRANE FILTER EFFI-CIENCY FOR PURIFICATION OF NATURAL WATER FROM WATER SUPPLY FACILITIES OF SUE "PETROPAVLOVSKY VODOKANAL"

Potapov V.V., Scientific research geotechnological center FED RAS, city of Petropavlovsk-Kamchatsky;
Brovkin A.E., SUE "Petropavlovsky Vodokanal", city of Petropavlovsk-Kamchatsky

Molecular weight of the structure of dissolved organic matter in natural water from water supply facilities of SUE "Petropavlovsky Vodokanal" was researched. Study was done by gel permeation chromatography. In tabular form indicated characteristics of the samples were studied. Integral curves of molecular weight distribution of investigated samples of dissolved organic substances were given. We considered the experimental data on using membrane filters for water purification in water treatment plant of SUE "Petropavlovsky Vodokanal". The issues of practical application of membrane filters, their advantages and disadvantages were examined. The report was done on the results of experiments applying ceramic microfiltration filters with a pore diameter 0,2 and 0,07 mkm for natural waters in SUE "Petropavlovsky Vodokanal" as well as to reduce the humus concentration and turbidity of natural waters using ultrafiltration filter. High efficiency of membrane devices for purification of natural water intake structures SUE "Petropavlovsky Vodokanal" with selectivity for microfiltration filters for humus concentration – up to 84 %, for turbidity – up to 100 %, for the ultrafiltration filter – for humus concentration – up to 80 % for turbidity – up to 100 % was experimentally established. The introduction of considered technological scheme of a new generation of water treatment Kamchatka Territory will significantly increase the efficiency of purification of natural water.

Key words: molecular weight distribution of dissolved organic substances, membrane filters, water turbidity, filter membrane selectivities.

УДК 628.162

РАСТВОРИМОСТЬ ОЗОНА В ВОДЕ ПО ВЫСОТЕ СТОЛБА ЖИДКОСТИ

Романовский В.И. ¹,
канд. техн. наук, ст. преподаватель кафедры промышленной экологии;
Гуринович А.Д. ², д-р тех. наук, профессор кафедры инженерной охраны окружающей среды;
Лихавицкий В.В.¹, ассистент кафедры автоматизации производственных процессов и электротехники
¹ Белорусский государственный технологический университет, г. Минск, Белоруссия;
² Белостоцкий технический университет, г. Белосток, Польша

Изучения закономерностей растворения озона в воде по высоте столба жидкости от параметров обработки являются необходимыми для разработки новых технологий дезинфекции сооружений водоснабжения с использованием озона. Представленные в литературе сведения по растворимости озона в воде позволяют рассчитать только равновесную концентрацию в системе «жидкость-газ» без учета других факторов.
Исследования проводили на двух экспериментальных установках для получения следующих параметров: время обработки, расход газовой смеси, концентрация озона в газовой смеси, высота слоя жидкости.
Результаты исследований для каждой из установок представлены в виде зависимостей концентрации остаточного озона в воде от выбранных параметров обработки и отображены графически. Описано влияние каждого из изменяемого параметра на остаточную концентрацию озона в воде, а также приведены факторы, влияющие на увеличение концентрации растворенного озона в воде по высоте на первых 3 м.
Получены математические модели, позволяющие описать зависимость концентрации озона в воде от заданных параметров: высоты от точки ввода газовой смеси, концентрации озона в газовой смеси, времени обработки, расхода газовой смеси. Проведена проверка значимости полученных уравнений регрессии.

Ключевые слова: дезинфекция, обеззараживание, водоснабжение, сооружения, озон, растворимость.

OZONE SOLUBILITY IN WATER IN HEIGHT OF THE LIQUID

Ramanouski V.I.,
Ph.D. of technical science, senior lecturer of department of industrial ecology;
Hurynovich A.D., Dr. habil. of technical sciences, professor of department of engineering environmental protection;
Likhavitski V.V., assistant of the department of automation of production processes and electrical engineering ,
¹ Belarusian state technological university, city of Minsk, Belarus;
² Belostotsky technical university, city of Bialystok, Poland

Study of the ozone dissolving in water height of the liquid column of the pro-cessing parameters are necessary for the development of new water supply facilities disinfection technology using ozone. Presented in the literature information on the solubility of ozone in water is allows only to calculate the equilibrium concentration without considering other factors. The investigations have been carried out on two experimental apparatuses. The following parameters as time processing, flow of the gas mixture, the concentration of ozone in the gas mixture, the height of the liquid layer have been studied. Research results for each apparatus are presented in the graphical form of depend-ences of the con­centrations of residual ozone in water from the selected processing pa-rameters. The influence of each variable parameter on residual ozone concentration in the water has been described, and the factors that affect the increase of the concentra-tion of ozone dissolved in water at the height of the first 3 m have also been shown.
Such mathematical models describing the dependence of the concentration of ozone in the water from the set parameters as the height of the insertion point of the gas mixture, the concentration of ozone in the gas mixture, processing time, flow of the gas mixture are presented. The significance of the regres­sion equations has been checked out.

Key words: disinfection, water supply, facility, ozone solubility.

УДК 631.1.017

СИСТЕМЫ ГОРЯЧЕГО ВОДОСНАБЖЕНИЯ С ЭЛЕКТРОНАГРЕВОМ ВОДЫ: ОБЛАСТИ ПРИМЕНЕНИЯ В СЕЛЬСКОМ ХОЗЯЙСТВЕ

Оболенский Н.В.,
д-р техн. наук, профессор, E-mail: obolenskinv@mail.ru;
Шевелев А.В., аспирант, E-mail: shevelev522@mail.ru
Нижегородский государственный инженерно-экономический университет, г. Княгинино, Нижегородская обл.

В статье произведен анализ современного состояния систем теплообеспечения сельскохозяй­ственных объектов, показавший, что применяемое теплоэнергетическое оборудование морально устарело, требует ремонта или замены. Выяснилось, что с целью обеспечения теплом сельскохозяй­ственных производственных объектов используются малоэффективные, несовершенные системы и технические средства теплообеспечения (центральные котельные), которые, в свою очередь, чрез­мерно капиталоемки и не в состоянии обеспечить требуемые нормированные условия содержания животных, обладают большими теплопотерями при значительном перерасходе топлива (мазут, печное топливо). Все эти факторы приводят к значительному снижению технико-экономических по­казателей. Проанализировано состояние отечественного машиностроения в области производства теплового оборудования, которое, как оказалось, также находится в плачевном состоянии. Выявле­ны основные факторы, способствовавшие возникновению сложившейся ситуации.
В качестве альтернативного, более рационального энергоресурса рассматривается электро­энергия, т.е. внедрение электронагрева. Описаны основные области применения электронагрева в различных отраслях сельского хозяйства (растениеводство, животноводство, эксплуатация МТП и т.п.) как внутри страны, так и мировом сельском хозяйстве, где наблюдается тенденция постоянного роста энергоемкости электротермических процессов. Рассмотрены преимущества и недостатки электронагрева, выявлена проблематика эффективного его применения, произ­ведена классификация технических средств электронагрева, перечислены основные требова­ния, предъявляемые к электротермическому оборудованию. Установлено, что использование электроэнергии в качестве источника теплоты приводит к достижению ряда положительных результатов, начиная от улучшения условий труда, заканчивая снижением вредных выбросов в окружающую среду.

Ключевые слова: водонагрев, мощность, оборудование, отопление, потребитель, произ­водство, процесс, ресурс, система, теплоноситель, теплообеспечение, техническая установка, электронагрев, энергия.

HOT WATER SYSTEM WITH HEATING WATER: APPLICATION IN AGRICULTURE

Obolenskiy N.V.,
Dr. habil. of technical sciences, professor;
Shevelev A.V., graduate student,
Nizhny Novgorod state engineering-economic university, city of Knyaginino, Nizhniy Novgorod region

The article made an analysis of the current state of heat supply systems of the agricultural sites showed that the applied heat power equipment outdated, in need of repair or replacement. It turned out that for the purpose of supplying heat agricultural production facilities are inefficient, imperfect systems and tools heating (Central boiler), which in turn excessively capital-intensive and unable to provide the required standardized animal welfare, have great heat loss at considerable over-expenditure of fuel (fuel oil, heating oil). All these factors lead to a significant reduction of technical and economic indica­tors Analyzes the state of domestic engineering in the field of production of thermal equipment, which, as it turns out, is also in poor condition. There are main factors contributing to the situation.
As an alternative, more rational energy resource considers the power, i.e. the introduction of electric heating. Describes the main areas of application of electrical heating in different sec-tors of agriculture (crops, livestock, operation, ICC, etc.) both within the country and world agri-culture, where there is a tendency of constant growth of consumption of electro thermal process-es. The advantages and disad­vantages of electric heating, identified the problem of efficient use of produced classification of technical means of electrical heating, are the main requirements of electro thermal equipment. It is established that the use of electricity as a heat source leads to the achievement of some positive results, ranging from improving working conditions, to reducing harmful emissions into the environment.

Key words: water heating, power, equipment, heating, consumer, manufacturing, process, resource, system, coolant, heating, technical installation, electric heating system, energy.

УДК 644.62

КОМБИНИРОВАННАЯ СИСТЕМА ЦЕНТРАЛИЗОВАННОГО ТЕПЛОСНАБЖЕНИЯ И ГОРЯЧЕГО ВОДОСНАБЖЕНИЯ НА БАЗЕ ТЭЦ И КВАРТАЛЬНЫХ ТЕПЛОВЫХ НАСОСОВ

Шит М.Л.,
канд. техн. наук, ведущий научный сотрудник лаборатории энергетической эффективности и возобновляемых источников энергии;
Бурчиу В.И., канд. техн. наук, заведующий лабораторией энергетической эффективности и возобновляемых источников энергии,
Институт энергетики АН Молдовы, г. Кишинев, Республика Молдова

В статье рассмотрена система теплоснабжения, в которой часть теплоты обратной сетевой воды тепловой электростанции используется для подачи теплоты к испарителям квартальных тепло­вых насосов отопления и горячего водоснабжения. Рассматриваются тепловые насосы на диокси­де углерода. В переходный и летний период тепловые насосы системы горячего водоснабжения работают с использованием теплоты окружающего воздуха. Теплота окружающего воздуха используется в промежуточном теплообменнике между первой и второй ступенями тепловых насосов для охлаждения газа после первой ступени компрессора теплового насоса, для охлажде­ния воды, подаваемой на вход испарителя теплового насоса (при необходимости) и хладагента на выходе газоохладителя теплового насоса.

Ключевые слова: тепловой насос, диоксид углерода, комбинированная система теплоснабжения.

DISTRICT HEATING SYSTEM USING HEAT PUMP INSTALLATIONS AND CHP

Shit M.L.,
Ph.D. of technical science, leading researcher of laboratory of energy efficiency and renewable energy resources;
Burciu V.I., Ph.D. of technical science, head of the laboratory of energy efficiency and renewable energy resources,
Institute of power of AS of Moldova, city of Chisinau, Republic of Moldova

The article describes the district heating system, in which part of the heat of return water thermal power is used to supply heat to the district heating pumps, evaporators heating and hot water. Heat pumps use carbon dioxide as refrigerant. During the transitional period of the year, and the summer heat pump for preparing hot-water supply system uses the heat of the surrounding air. The heat of the ambient air is used in the intermediate heat exchanger between the first and second stages of the heat pump to cool the gas after the first stage of the compressor of the heat pump.

Key words: district heating, carbon dioxide heat pump.

УДК 621.577, 62-67

УНИВЕРСАЛЬНАЯ СИСТЕМА КОМПЕНСАЦИИ НАГРУЗКИ ГВС

Иванов С.А.,
д-р техн. наук, профессор;
Батухтин А.Г., канд. техн. наук, доцент;
Кобылкин М.В., аспирант, инженер;
Басс М.С.,
Забайкальский государственный университет, г. Чита

В статье рассмотрена энергоэффективная система теплоснабжения с применением теплово­го насоса, предназначенная для покрытия нагрузки ГВС в неотопительный период. В качестве источника низкопотенциального тепла в системе предлагается использовать систему отопления здания.

Ключевые слова: тепловой насос, энергосбережение, горячее водоснабжение, малозатратность.

UNIVERSAL SYSTEM OF COMPENSATION OF LOADING OF HWS

Ivanov S.A.,
Dr. habil. of technical sciences, professor;
Batukhtin A.G., Ph.D. of technical science, associate professor;
Kobylkin M.V., postgraduate student, engineer;
Bass M.S.
Transbaikal state university, city of Chita

The article considers the energy efficient heating system with a heat pump, designed to cover the hot water load in not-heating period. As low-temperature heat source in the system is suggested to use the building heating system.

Key words: heat pump, energy, hot water, low-cost.

УДК 628.1

ПИТЬЕВОЕ ВОДОСНАБЖЕНИЕ ГОРОДА ПЕРМИ

Тихонова Н.А.,
магистрант;
Мелехин А.Г., д-р техн. наук, заведующий кафедрой теплоснабжения, вентиляции и водоснабжения, водоотведения,
Пермский национальный исследовательский политехнический университет, г. Пермь

В статье рассмотрены основные источники водоснабжения города Перми, альтернативные источники водоснабжения, а также будет предложен метод очистки питьевой воды на кустовых водоочистных станциях. Также в статье представлены основные параметры воды на входе и выходе с очистных сооружений, качественный анализ основных марок бутилированной воды. Рассмотрены основные типы бытовых фильтров, их достоинства и недостатки, система питьевого водоснабжения на кустовых водоочистных станциях, а также приведено обоснование предлагае­мого метода очистки.

Ключевые слова: водоснабжение, качественная вода, питьевая вода, бутилированная вода, фильтровальная вода, вода на розлив, очистные сооружения, альтернативный источник, филь­тры, кустовые станции, система подготовки питьевого водоснабжения, загрязнения, параметры качества воды, санитарные нормы и правила, транспортировка.

DRINKING WATER SUPPLY OF THE CITY OF PERM

Tikhonova N. A., undergraduate;
Melekhin A.G., Dr. habil. of technical sciences, head of the department of heat supply, ventilation and water supply, water disposal,
Perm national research polytechnical university, city of Perm

The article discusses the main sources of water supply of the city of Perm, alternative sources of water supply and the method of purification of drinking water well sewage treatment plants.
The qualitative course of the advertising business has convinced people that the use of alternative sources, they receive high quality drinking water that meets all regulatory requirements. Obviously, the water obtained in this way has no smell, no taste, and if we add sweeteners, it will still tasty, but tasty water, it is still not useful. We all know what huge role water plays for the life and development of our body.
Also in the article, we present the main parameters of water at the inlet and outlet of the treatment plant, provides a qualitative analysis of the major brands of bottled water, describes the main types of household filters, their advantages and disadvantages discussed the drinking water system on well water treatment stations, and provides the rationale for the proposed cleaning method.

Key words: water, quality water, drinking water, bottled water, water filter, water filling machine, water treatment facilities, alternative source, filters, Bush station system potable water supply, pollution, water quality parameters, sanitary norms and rules, transportation.

Питьевое водоснабжение города Перми

В статье рассмотрены основные источники водоснабжения города Перми, альтернативные источники водоснабжения, а также будет предложен метод очистки питьевой воды на кустовых водоочистных станциях. Также в статье представлены основные параметры воды на входе и выходе с очистных сооружений, качественный анализ основных марок бутилированной воды. Рассмотрены основные типы бытовых фильтров, их достоинства и недостатки, система питьевого водоснабжения на кустовых водоочистных станциях, а также приведено обоснование предлагаемого метода очистки.

Авторы: Тихонова Н.А, Мелехин А.Г

Универсальная система компенсации нагрузки гвс

В статье рассмотрена энергоэффективная система теплоснабжения с применением теплового насоса, предназначенная для покрытия нагрузки ГВС в неотопительный период. В качестве источника низкопотенциального тепла в системе предлагается использовать систему отопления здания.

Авторы: Иванов С.А, Батухтин А.Г, Кобылкин М.В, Басс М.С

Комбинированная система централизованного теплоснабжения и горячего водоснабжения на базе ТЭЦ и квартальных тепловых насосов

В статье рассмотрена система теплоснабжения, в которой часть теплоты обратной сетевой воды тепловой электростанции используется для подачи теплоты к испарителям квартальных тепловых насосов отопления и горячего водоснабжения. Рассматриваются тепловые насосы на диоксиде углерода. В переходный и летний период тепловые насосы системы горячего водоснабжения работают с использованием теплоты окружающего воздуха. Теплота окружающего воздуха используется в промежуточном теплообменнике между первой и второй ступенями тепловых насосов для охлаждения газа после первой ступени компрессора теплового насоса, для охлаждения воды, подаваемой на вход испарителя теплового насоса (при необходимости) и хладагента на выходе газоохладителя теплового насоса.

Авторы: Шит М.Л, Бурчиу В.И, Burciu V.I

Системы горячего водоснабжения с электронагревом воды: области применения в сельском хозяйстве

В статье произведен анализ современного состояния систем теплообеспечения сельскохозяйственных объектов, показавший, что применяемое теплоэнергетическое оборудование морально устарело, требует ремонта или замены. Выяснилось, что с целью обеспечения теплом сельскохозяйственных производственных объектов используются малоэффективные, несовершенные системы и технические средства теплообеспечения (центральные котельные), которые, в свою очередь, чрезмерно капиталоемки и не в состоянии обеспечить требуемые нормированные условия содержания животных, обладают большими теплопотерями при значительном перерасходе топлива (мазут, печное топливо). Все эти факторы приводят к значительному снижению технико-экономических показателей. Проанализировано состояние отечественного машиностроения в области производства теплового оборудования, которое, как оказалось, также находится в плачевном состоянии. Выявлены основные факторы, способствовавшие возникновению сложившейся ситуации. В качестве альтернативного, более рационального энергоресурса рассматривается электроэнергия, т.е. внедрение электронагрева. Описаны основные области применения электронагрева в различных отраслях сельского хозяйства (растениеводство, животноводство, эксплуатация МТП и т.п.) как внутри страны, так и мировом сельском хозяйстве, где наблюдается тенденция постоянного роста энергоемкости электротермических процессов. Рассмотрены преимущества и недостатки электронагрева, выявлена проблематика эффективного его применения, произведена классификация технических средств электронагрева, перечислены основные требования, предъявляемые к электротермическому оборудованию. Установлено, что использование электроэнергии в качестве источника теплоты приводит к достижению ряда положительных результатов, начиная от улучшения условий труда, заканчивая снижением вредных выбросов в окружающую среду.

Авторы: Оболенский Н.В, Шевелев А.В

Растворимость озона в воде по высоте столба жидкости

Изучения закономерностей растворения озона в воде по высоте столба жидкости от параметров обработки являются необходимыми для разработки новых технологий дезинфекции сооружений водоснабжения с использованием озона. Представленные в литературе сведения по растворимости озона в воде позволяют рассчитать только равновесную концентрацию в системе «жидкость-газ» без учета других факторов. Исследования проводили на двух экспериментальных установках для получения следующих параметров: время обработки, расход газовой смеси, концентрация озона в газовой смеси, высота слоя жидкости. Результаты исследований для каждой из установок представлены в виде зависимостей концентрации остаточного озона в воде от выбранных параметров обработки и отображены графически. Описано влияние каждого из изменяемого параметра на остаточную концентрацию озона в воде, а также приведены факторы, влияющие на увеличение концентрации растворенного озона в воде по высоте на первых 3 м. Получены математические модели, позволяющие описать зависимость концентрации озона в воде от заданных параметров: высоты от точки ввода газовой смеси, концентрации озона в газовой смеси, времени обработки, расхода газовой смеси. Проведена проверка значимости полученных уравнений регрессии.

Авторы: Романовский В.И. 1, Гуринович А.Д. 2, Лихавицкий В.В. 1, Ramanouski V.I, Hurynovich A.D, Likhavitski V.V